- Contact Person : Mr. Yi John
- Company Name : Shenzhen Kinglife Environmental Technology Co., Ltd.
- Tel : 86-755-83419451
- Fax : 86-755-83419451
- Address : Guangdong,Shenzhen,2F, Tianfa Building CD Block, Tian'an Cyber Park, Futian District, Shenzhen, China
- Country/Region : China
- Zip : 518040
2000Liter Per hour,UF Water treatment system
Ultrafiltration using hollow fiber filtration technology, with the three pre-processing filtersto remove water impurities; microporous ultrafiltration of less than 0.01 micron, cancompletely filter out bacteria, rust, colloids and other harmful substances, to retain the water of the originaltrace elements and minerals.
Description of the Whole UF Water treatment systemOperating system: (24 hours) WorkingWater supply: Continuous water supplyMode of operation: Interlock control system,Some Part manual operation
Design of the UF Water treatment system
Water source: Physical and chemical indicators have reached the standard of local water purificationThe quality of raw water: According to water test reportWater quality: The barrels / bottled water purification standardsProduction capacity:2000L/h (25 °C)
Design: from the entrance to the installation of water purification water purification equipment exports
Configuration of the UF water treatment System
Water pre-treatment system: Quartz sand filters, Activated carbon filters, Precision filters;Chemical dosing machine.
Main filtration system: Consists by hollow ultra filtration device
Supporting systems: The electrical control system.
Water treatment system installed on the basic requirements of the external
Supply & Drain system:Supply auxiliary equipment to the water treatment room, water pressure ≥0.2 Mpa, water usage:4M3/ h, there should be room to leakage and drainage gutter.
Electronic Supply:Water treatment rooms set up within the distribution box, the total power capacity of 1 KW;
The device configuration and performance
(1) The original pumps: stainless steel centrifugal pump
Performance parameters:Model: BLC70/0.75KWMaterial: 304 Stainless SteelFlow rate: 4m3 / HHead: 30mSpeed: 2900/minOrigin: GuangdongQuantity: 1
(2) Quartz sand filter: The high-quality 304 stainless steel with a valve operating system, pipeline system, containing the manhole, hand hole, the upper and lower water distribution devices, media, pressure. Performance parameters:Model: WTG-300Forms: pressure automatic operation, manual recoilEquipment operating flow rate: 16m / hFlow rate: 4m3 / HDesign pressure: 0.6MpaDiameter: Ø300mmEquipment Height: 1200mmThickness: 1.2mmMaterial: SUS304Filter story: 300mmFilter: refined quartz sandSize :1-2 .5 mmConfiguration: Operating valve Ø 32 five, the other pipe fittings, etc.Operation screen bracket (stainless steel)Out of the water pressure gauge 1Quantity: 1
(3) Activated carbon filter: high-quality 304 stainless steel with a valve operating system, piping system, containing the manhole, hand hole, up and down the water distribution unit, filter, pressure type. Performance parameters:Model: WTG-300Forms: pressure automatic operation, manual recoilEquipment operating flow rate: 16m / hFlow rate: 4m3 / HDesign pressure: 0.6MpaDiameter: Ø300mmEquipment Height: 1200mmThickness: 1.2mmMaterial: SUS304Filter story: 300mmFilter: refined activated carbonSize :8-16 meshConfiguration: Operating valve Ø 32 five, the other pipe fittings, etc.Operation screen bracket (stainless steel)Out of the water pressure gauge 1Quantity: 1(4) Precision filters: high-quality stainless steel, containing the filter with a fixed bracket. Performance parameters:Model: WTJ300Forms: external pressureFlow rate: 4m3 / hDesign pressure: 0.3MPaEquipment Height: 500mmFilter: melt-blown polypropylene 5umCartridge number: 4Quantity: 1(5) The hollow ultrafiltration devices: the use of hollow membrane system, with 304 stainless steel frame, famous film membrane components using days, Hangzhou, south of drug wash pump is stainless steel produced multi-stage pumps. Electrical automatic control AC contactor controller, comes with a flow meter, pressure gauge, automatic flush valve and so on.Protection device: the booster pump with water before and after low water and high pressure switch, water does not prevent the systemEnough pressure is too low, and high-pressure pump to stop operation of the system. As a high-pressure pump caused the water pressure is too high, stop the booster pump power, the overpressure protection system operation.Performance parameters:Model: RO-1000I (2000L / H) before ultrafiltration systemWater production ≥ 2m3 / h (25 °C) waterRecovery rate: ≥ 75 ~ 90%Operating pressure :0.1-0 .3 MpaForm: automatic control, automatic washingIncluding equipment:Hollow membraneModel: 4040Pressure :20-30piMaterial: aromatic polyamide composite membraneProduction: national bestQuantity: 4(6) Instrumentation and electrical control system A, Famous electrical componentsB, Low voltage switchC, Level control switchD, FlowmeterE, Pressure gaugeF, Stainless steel electrical control box(7) Installation Material A, Wire and cable, stainless steel stentB, Ø32 sanitary pipeC, Sanitary Valves
UltrafiltrationUltrafiltration is a pressure driven membrane separation technologies. Separation ofmacromolecules and small molecules for the purpose of the membrane pore size in the20-1000A °. The hollow fiber ultrafilter (membrane) has a filling unit containers, high density, small footprint advantages.
Ultrafiltration processUltrafiltration process, the aqueous solution under pressure-driven flows through themembrane surface, less than the membrane pore solvent (water) and small solutespermeable membrane purification liquid (liquid filtration) than the membrane pore-soluteand solute Group are retained, with the water discharge, a concentrated solution.Ultrafiltration process for dynamic filtration, separation is completed in the current state.The Solute only limited deposition on the membrane surface, the ultrafiltration rate ofdecay to a certain extent and balanced, and can be restored by cleaning.
Origin of ultrafiltrationThe origin of ultrafiltration So in 1748, Schmidt Cotton film or Lu membrane filter solution,exert a certain pressure, the solution (water) through the membrane, proteins, colloidsand other substances were interception down far more than its filtering accuracy filter paper, and he proposed ultrafiltration phrase in 1896, Martin, the system out of the firstartificial ultrafiltration membrane, its the 1960s, the concept of molecular scale, is the beginning of modern ultrafiltration in the 1970s and 1980s period of rapid developmentafter the 1990s began to mature. China the technology of late 1970s, is still in theresearch period in the late 1980s before moving on to industrial production and application stages.
2000Liter Per hour,UF Water treatment system